E-PLUS Image Release History
Version Release Date   Changes
       
8.00.43 4/12/2021 1. Supported Foxboro Sensor Different Range
  2. Added ISO6976-2016 Heating Value (Gross Method)
   
8.00.42 10/18/2019   1. Added Foxboro Transmitter Interface
       
8.00.41 3/21/2019   1. Increased DP Resolution for 4-20mA Input
       
8.00.40 5/30/2018   1. Reset Turbine Offset at Startup
       
8.00.39 11/18/2016 1 .Added Calorific Calculation
  2. Corrected Energy Flow Calculation (Metric Units)
  3. Replaced Mass Units "TON" with "TONNE"
       
8.00.38 11/25/2015   1. Added Last 24 Hours Chart
  2. Reset RAM after Loading the New Firmware
       
8.00.37 9/4/2014   1. Added Modbus Registers 7024-7025
  2. Added Switch Output Wiring Selection
       
8.00.36 2/7/2014   1. Added BS&W for Liquid Meter 
  2. Correction - Reset Reynolds Number Flag if Not Used (Cone Meter)
       
8.00.35 10/24/2013   1. Added Reynolds Number Linear Factors for SmartCone Meter
       
8.00.34 10/29/2012   1. Modified Communication Routine
  2. Modified Sdevice Timer
  3. Corrected Spare#3/#4 in the Historical Report
  4. Added Modbus Address 7185-7187 Multivariable Numeric DP/Pressure/Temperature Value
  5. Reset Pressure/Temperature/BS&W Override Value if Nothing is Assigned to the Input
       
8.00.33 5/14/2012 1.Added Accelabar Flow Equation (Natural Gas)
   
8.00.32 4/27/2012   1. Correction - Display Assignments 43 and 44 
  2. Modified Download Mode 
       
8.00.31 1/17/2011   1. Added Ammonia Equation
       
8.00.30 6/29/2011   1. Added Zb and Z Factor
  2. Modified Status/Frequency Input Reinitialzation
       
8.00.29 12/3/2010   1. New Display Contrast Initialization
       
8.00.28 8/27/2010   1.Modified Display Contrast to Support Version1 and Version2 Display
       
8.00.27 8/6/2010   1.Modified the Display Contrast
       
8.00.26 4/28/2010   1. Added 16 Bits Registers for V-Cone Application
       
8.00.25 3/31/2010   1. Added New Display Driver
  2. Modified Reset Routine
       
8.00.24 1/28/2010   1. Modified to Display Guage Pressure Only
  2. Modified Serial Communication Routine
  3. Modified Enron Alarm/Event Routine
       
8.00.23 11/1/2009   1. Added GE GHM80 Mass
       
8.00.22 10/8/2009   1. Added CHOKE Equation
  2. Added Momentary Switch Output Option
       
8.00.21 11/26/2008   1. Added VenCone Flow Equation
  2. Added BLM Display Option
       
8.00.20 8/26/2008   1. Added Critical Control Registers
       
8.00.19 4/12/2008   1. Correction - ISO5167 - 2003 Factors
       
8.00.18 3/11/2008 1. Correction - Reset Spare Data Variables
   
8.00.17 9/12/2007   1. Added ISO5167-2003 Equation
       
8.00.16 9/12/2007   1. Correction - Historical Hourly Program Variables
   
8.00.15 8/20/2007   1. Correction - Verification Report - RTD/Analog Inputs
   
8.00.14 6/27/2007   1. Correction - External RTD Diagnosis
   
8.00.13 6/15/2007   1. Added Factory Test
       
8.00.12 10/6/2006   1. Correction - Wrong Version Number 
  2. New Rosemount Average Rountine
       
8.00.11 9/22/2006   1. Read Rosemount Transmitter Type
       
8.00.10 8/16/2006   1. Correction - Bluetooth Re-Connection
  2. Disable Plunger Checking in Diagnostic Mode
  3. Add Plunger Start Delay Timer
       
8.00.09 5/19/2006   1. Add Barrel Flow Unit Selection
  2. Correction - Plunger Lift Stage Flag
       
8.00.08 5/3/2006   1. Add Saturated Steam Calculation
  2. Add Venturi Equation
  3. Add Plunger Lift Early Arrival Protection 
  4. Add Audit Trail Entries - Date, Time, and Heating Value Override
  5. Add Bluetooth
       
8.00.07 4/3/2006   1. Add Customer Storage Option
  2. Add Time Based Plunger Lift Control
  3. Add Flow Unit Selection - M3 and CF
       
8.00.06 1/19/2006   1. Correction - Graphic Display - Daily FWA Value
       
8.00.05 7/19/2005   1. Add Flow Set Point Selection for PID Control
       
8.00.04 7/5/2005   1. Correction - Steam Energy Flow Calculation
  2. Correction - Display Unit is Based on the Flow Unit Selection
       
8.00.03 3/22/2005   1. Add New Modbus Registers - Yesterday's Flow Time in Minutes and in Seconds
  2. Correction - Active Alarms (Display)
  3. Check SG Limit only if AGA8 Gross Method 2 Is Used.
  4. Add Graphical DFM Logo
       
8.00.02 3/8/2005   1. Add - Daylight Saving Time Option
  2. Add - Steam Calculation
  3. Add - 5 Sets of Program Variable Statements
  4. Change - Save up to 840 Historical Hourly Reports.
       
8.00.01 1/6/2005   1. Set Auxiliary Meter Default to Zero
  2. Add Orifice Plate Selector
  3. Add BS&W Input
       
8.00.00 11/1/2004   1. First Release