MICROMG Image Release History |
|
|
|
|
|
|
|
|
|
|
Version |
Release Date |
|
Changes |
|
|
|
|
|
|
|
|
|
|
11.00.15 |
5/13/2022 |
|
1. Increased 6 point linearization configuration data. |
|
|
|
|
|
|
2. Added AGA8 Zf and Zb to the System Snapshot Report |
|
|
|
|
|
|
3. Added yesterday gross total in FC display. |
|
|
|
|
|
|
|
|
|
|
11.00.16 |
5/13/2022 |
|
Customized Version |
|
|
|
|
|
|
|
|
|
|
11.00.14 |
8/6/2021 |
|
1. Supported different ranges of Foxboro Sensor |
|
|
|
|
|
|
2. Added an option to use ISO2016 Gross or Net Heating
Value Method |
|
|
|
|
|
|
3. Added Modbus Registers, ISO2016 Gross Heating Vaue,
9077 (Meter#1), 9277(Meter#2) |
|
|
|
|
|
|
|
|
|
|
11.00.13 |
8/6/2021 |
|
Customized Firmware (Modbus Shift
2x16 bit IEEE floating register) |
|
|
|
|
|
|
1. Supported different ranges of Foxboro Sensor |
|
|
|
|
|
|
2. Added an option to use ISO2016 Gross or Net Heating
Value Method |
|
|
|
|
|
|
3. Added Modbus Registers, ISO2016 Gross Heating Vaue,
9077 (Meter#1), 9277(Meter#2) |
|
|
|
|
|
|
|
|
|
|
|
12/10/2021 |
|
1. Corrected pressure decimal points issue |
|
|
|
|
|
|
2. Modified battery voltage conversion routine |
|
|
|
|
|
|
|
|
|
|
11.00.12 |
3/16/2021 |
|
1. Customized Firmware (Modbus
Shift 7 - 2x16-bit IEEE floating
register) |
|
|
|
|
|
|
2. Added 7301-7349: 2x16-bit IEEE floating registers |
|
|
|
|
|
|
|
|
|
|
11.00.11 |
3/16/2021 |
|
1. Increased Modbus Shift Range |
|
|
|
|
|
|
|
|
|
|
11.00.10 |
12/23/2020 |
|
1. Displayed spare input tag ID |
|
|
|
|
|
|
|
|
|
|
11.00.09 |
11/3/2020 |
|
1. Corrected Frozen Flow Rate |
|
|
|
|
|
|
|
|
|
|
11.00.08 |
8/20/2020 |
|
1. Added ISO6976-2016 Heating
Value |
|
|
|
|
|
|
2. Added Foxboro Transmitter Interface |
|
|
|
|
|
|
|
|
|
|
11.00.07 |
6/26/2020 |
|
1. Corrected Metric Units |
|
|
|
|
|
|
2. Revised hourly report polling method |
|
|
|
|
|
|
3. Modified AGA7/Freqency code |
|
|
|
|
|
|
4. Increased RS485-Master port timer |
|
|
|
|
|
|
|
|
|
|
11.00.06 |
2/28/2018 |
|
1. Improved GC updating time |
|
|
|
|
|
|
2. Replaced density with SG |
|
|
|
|
|
|
3. Corrected analog output calibration |
|
|
|
|
|
|
|
|
|
|
11.00.05 |
1/30/2018 |
|
1. Add energy units optoins -
MMBTU or MBTU (US Units), GJ or MJ (Metric Units) |
|
|
|
|
|
|
|
|
|
|
11.00.04 |
3/22/2017 |
|
1. Gas Chromatograph - Added
option to select 2x16-bit or 1x32-bit floating register |
|
|
|
|
|
|
|
|
|
|
11.00.02 |
2/24/2017 |
|
1. Added calibration mode option
prior to execution of calibration |
|
|
|
|
|
|
2. Added calibration and verification report |
|
|
|
|
|
|
3. Added 3 point calibration option |
|
|
|
|
|
|
4. Added option for selectioning averaging method |
|
|
|
|
|
|
5. Added GC slave status |
|
|
|
|
|
|
6. Modified historical report templates registers |
|
|
|
|
|
|
|
|
|
|
11.00.01 |
11/7/2016 |
|
1. Modified Historical Report
Templates |
|
|
|
|
|
|
2. Changed Maximum Number of Hourly Reports |
|
|
|
|
|
|
|
|
|
|
11.00.00 |
11/1/2016 |
|
1. First Release |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|