| MicroML1 Release History | ||||
| Note: Changes in black mean new features or capabilities and red changes mean corrections from previous versions. | ||||
| Version | Release Date | Changes | ||
| 2.15 | 10/8/2025 | Corrected Historical Report issues | ||
| Solved Windows 11 compatibility issues | ||||
| *Note It is required to delete registry after uninstaling the old and before installing this version 2.15 |
||||
| 2.14 | 10/18/2024 | Corrected Historical Report issues | ||
| Corrected to connect to a wrong type of Flow Computer. | ||||
| Corrected configuration data entries issues | ||||
| Corrected security code functions | ||||
| *Note It is required to delete registry after uninstaling the old and before installing this version 2.14 |
||||
| 2.13 | 5/7/2016 | Corrected Com Port number issue | ||
| 2.12 | 8/24/2013 | Replaced Text "4-AGA7(Frequency)" with "4-Frequency" | ||
| 2.11 | 3/12/2013 | Implemented Downloader version 2.05 | ||
| Corrected system port number issues | ||||
| Corrected Autodetect issues | ||||
| Enabled Master Port | ||||
| 2.10 | 2/6/2013 | Implemented New Downloader | ||
| 2.9 | 1/31/2012 | Added Bluetooth Feature for E-Lite EXP | ||
| Modified Digital Input/Output Assignments | ||||
| Modified Communication Routine | ||||
| Modified Downloader Mode | ||||
| Multivariable Status register is added | ||||
| 2.8 | 6/5/2009 | Support for 1-5 Volt Inputs using the E-Lite Hardware | ||
| Addition of E-Lite and E-LiteEXP Wiring Drawings | ||||
| 2.7 | 6/25/2008 | Corrected flow rate average data entry. Was being increased by 1 | ||
| Modified Fc Diasplay Assignment descriptions | ||||
| 2.6 | 9/10/2007 | Added Support for V-Cone Meters | ||
| 2.5 | 7/30/2007 | Not updating ST/SW on the diagnostics screen | ||
| Automatically Maximize current view | ||||
| 2.4 | 2/23/2006 | Configuration download was not backward compatible with version 6.01.10 and older | ||
| Added support for E-Lite Hardware | ||||
| Revised PID Screen | ||||
| 2.3 | 8/23/2006 | Stack DP Configuration and Reporting not showing DP high Effect | ||
| 2.2 | 6/17/2006 | Added Third Variable to Injection Index Test Logs | ||
| 2.1 | 6/1/2005 | Increases Density decimal places to 4 | ||
| 2.0 | 5/18/2005 | New Modbus Shift | ||
| Expanded NIST14 Range | ||||
| Added HTML Views for diagnostic and PID | ||||
| Added Multitasking communications | ||||
| Added Ethernet Support | ||||
| 1.0.0.17 | 7/29/2004 | Data Averaging for Injectivity Test (Data Damping) | ||
| 1.0.0.16 | 4/23/2004 | DDE (Dynamic Data Exchange) Capabilities to the Injectivity Text. | ||
| Program Variables under IO configuration section (supports negative numbers) | ||||
| Issue not uploading table selection for tables 1 through 9. | ||||
| 1.0.0.15 | 3/2/2004 | Disabled 19200 Baud selection on communication ports to avoid user problems with RS232 conections. | ||
| Optimized Database Access when retrieving II Test Data (Reduced upload time by 40%) | ||||
| Reduced II Test Capacity from 33000 records to 30000 to match Flow Computer capacity. | ||||
| 1.0.0.14 | 3/2/2004 | When starting application a "File Not Found" appears due to a Modem Settings file missing, the problem was solved by creating a default modem settings file if it doesn't exist. | ||
| 1.0.0.13 | 11/20/2003 | Modem Communications | ||
| 1.0.0.12 | 9/15/2003 | Option to store Spare 1 or Spare 2 input instead of Meter Pressure in II Test | ||
| Modified II Test report to improve MSWord exported file | ||||
| Update Calibration windows to new easier process | ||||
| Fix II Test Timer rolling over after 8 hours - Needs firmware update | ||||
| 1.0.0.11 | 8/4/2003 | Add Flow Rate or DP Log Selection in II Test | ||
| 1.0.0.10 | 5/23/2003 | Add user-defined displays | ||
| Increase Plant Name from 8 to 16 characters | ||||
| Increase Screen delay from 4 to up to 20 seconds | ||||
| 1.0.0.9 | 5/6/2003 | Do Not Allow 0 as Modbus ID | ||
| Get un-collected data option in the reports | ||||
| Change II Test Stage Duration to Minutes | ||||
| Changed Hourly report to Hour/Day/Minute units | ||||
| Add Copy PC time button | ||||
| Display Selection 22 - Meter Information | ||||
| Option to see hourly report from Dynacom after collecting data. | ||||
| 1.0.0.8 | 4/15/2003 | Added File Version information in the configuration file | ||
| Included Injectivity Index Test (II-Test) functionality | ||||
| Improved Image File Downloading Window | ||||
| Increased PID Data Entry range from 2 to 9.9 | ||||
| 1.0.0.7 | 3/13/2003 | When viewing Audit Report records were not beign deleted from DB | ||
| Added RTS Selection (RTS or Printer) for Port 2 | ||||
| Added Rx/Tx indication lights | ||||
| Aramco's report gets appended to the file instead of creating a new file | ||||
| Default Fault Code was changed to zero (live) | ||||
| 1.0.0.6 | 2/25/2003 | Includes Spare Input display in the Snapshot Report | ||
| Includes Battery Voltage in Aramco's Hourly Report | ||||
| Allows Meter ID up to 16 characters (it was 8 Chars) | ||||
| Security check for incompatible previous version files. | ||||
| 1.0.0.5 | 1/23/2003 | Solved issues with Aramco's report | ||
| Ability to export configuration file to text | ||||
| Configuration file structure was modified to be compatible with future releases | ||||
| Added Plant Name tag into the configuration | ||||
| 1.0.0.4 | 11/4/2002 | Solved Crystal Reports Engine Issue | ||
| Was unable to calibrate in Full (2 points calibration) | ||||
| 1.0.0.3 | 9/8/2002 | Added Auto Detect Feature | ||
| Added "Save Changes" question when leaving program | ||||
| Able to configure device from any screen diff. Than diagnostics | ||||
| Had problem with data entry "disappearing" on current data | ||||
| Disabled Downloading Override Values with the Configuration | ||||
| Unable to edit Communication settings from a window diff. than diagnostics | ||||
| Report's units were not displaying correctly | ||||
| Added Application Tag on the About Box | ||||
| 1.0.0.2 | 9/8/2002 | Added MCF6.0 library to the setup (For Windows 98) | ||
| 1.0.0.1 | 6/11/2002 | First Release | ||