MICROML1 Image Release History
Version Release Date   Changes
       
6.03.14 5/24/2018 1. Increased Time for A/D Converter (Analog Inputs)
   
6.03.13 2/22/2018   1. Modified  Foxboro Transmitter Interface Routine
       
6.03.12 11/13/2017   1. Added Foxboro Transmitter Interface Routine
  2. Reduced Time for A/D Converter
       
6.03.11 1/10/2017   1. Corrected Display Text Issue - Meter ID, Flow Rate, and Batch Total
       
6.03.10     Test Version (N/A)
       
6.03.09 11/1/2015   1. Modified Display Routine
       
6.03.08 2/13/2014   1. Corrected PPMIX
       
6.03.07 9/9/2013   1. Corrected Analog Input#3 Reading
       
6.03.06 4/16/2013   1. Set Less Sensitivity Default Value for the Display Keys
  2. End Batch and Reset Flow Averaged Value if a New Flow Calculation Method is Applied.
       
6.03.05 3/13/2013   1. Modified Communication Routine
  2. Reduced Sdevice Timer
  3. Set Display Contrast Initialization to 35
  4. Set Double Write to Download Mode via RS232 Port
  5. Enabled Master Communication Port
  6. Correction - PPMIX
       
6.03.4 10/14/2011   1. Correction - New23/24 with Live Densitometer Temperature and Densitometer Pressure
       
6.03.3 3/31/2010   1. Modified Reset Routine
       
6.03.2 1/29/2010   1. Added Rosemount Meter Type
       
6.03.1 9/16/2009   1. Modified Display Initialization
       
6.03.0 3/20/2009   1. Added Support for Old and New Hardware Units
       
6.02.6 5/2/2008   1. Correction - NIST14 Fluid Mixtures
  2. Expand Range of NIST14 Calculation
       
6.02.05 3/13/2008   1. Correction - Reset Bi-Directional Configuration Variables
       
6.02.4 1/30/2008   1. Modify GPA-TP15 (2007)
  2. Add Battery Voltage and Application Display Selection
  3. New Rosemount Average Rountine
       
6.02.3 9/8/2007   1. Add V-Cone Flow Equation
       
6.02.2 1/8/2007   1. Correction - Expansion Analog Input Alarm Status
  2. Modify Display Sensitivity Key Routine
       
6.02.1 7/3/2006   1. Display Density in GM/CC not LB/FT3 on Diagnostic Screen 
  2. Correction - Gravity Out of Range Volume Re-Calculation for a New Product 
  3. Correction - Spare Data #2
  4. Add Custom Storage Selection (Maximum 3 Variables)
       
6.02.0 6/5/2006   1. Add Saturated Steam Selection
  2. Add Analog Input Expansion Option
  3. Delete Propylene/Ethylene/NBS1045 Equations
       
6.01.10 8/25/2005   1. Correction - Enron Modbus (Alarms/Audit Date)
       
6.01.9 6/27/2005   1. Correction - Modbus Shift 
       
6.01.8 6/16/2005   1. Correction - Port#2 Baudrate
  2. Add Enron Modbus Registers
       
6.01.7 5/31/2005   1. Correction - Enron Modbus
  2. Change Density to Have 4 Decimal Places
       
6.01.6 4/12/2005   1. Modify Modbus Shift Routine
  2. Modify Boolean Statement/Program Variable Statement Routine
  3. Enable/Disable Front Panel Scan Key
  4. Add Calibration Parameters to be Part of the Configuration Software
  5. DayLight Saving Time Option
  6. Expand Range of NIST14 Calculation
  7. Modify Hourly Data - Averaged Density or Averaged SG
  8. Add New Modbus Registers - Last Hour …
  9. Change Wait State to 1
       
6.01.5 7/30/2004   1. Add Roll Over Counters for Month and Cumulative Total Variables
  2. Correction - Update Hour, Day, Month and Batch Display Variables
       
6.01.4 7/29/2004   1. Add Test Average Period
  2. Add TPU Frequency 
       
6.01.3 5/20/2004   1. Correction - Broadcast Command
       
6.01.2 10/27/2003   1. Set New ROM/RAM Wait State
       
6.01.1 9/15/2003   1. Add 32 Bits II-Test Time Left Timer
       
6.01.0 9/12/2003   1. Add Ability to Store Spare Pressure for II-Test.
       
6.00.10 8/5/2003   1. Reset Device only if Multi.Variable Interface is Lost.
       
6.00.9 8/4/2003   1. Add DP or Net Flow Rate Log Selection
  2. Improve Real Time Clock Accuracy
  3. Improve Multi.Variable Interface Routine
       
6.00.8 5/23/2003   1. Add Custom Display Option
  2. Add New Modbus Register - Plant ID (20 Chars.)
       
6.00.7 5/6/2003   1. Add Un-Collected Report Counters
  2. Show Test Status on Display Screen
  3. Add Meter Information Display
  4. Change the duration of the stage in minutes instead of hours
   
6.00.6 4/15/2003   1. Add Injectivity Index test
       
6.00.5 2/19/2003   1. Add New Modbus Register (2568-2575) Meter ID (16 Chars.)
  2. Customized Hourly Report - Save Snapshot Date and Time
       
6.00.4 1/22/2003   1. Add Plant ID 
  2. Customized Hourly Report - Replace Cumulative Net Total with Daily Net Total 
  3. Customized Hourly Report - Replace Hourly Net Total with Daily Net Total
  4. Customized Hourly Report - Save DP High and DP Low Value
       
6.00.3 9/30/2002   1. Set Wait State to 3
       
6.00.2 9/13/2002   1. Increase Totalizer Resolution
       
6.00.1 9/6/2002   1. Increase DP Range of Muliti-Variable to 1075