MICROML4 Image Release History |
|
|
|
|
|
|
Version |
Release Date |
|
Changes |
|
|
|
|
|
|
6.01.12 |
7/15/2024 |
|
1. Added Floating Mode Option |
|
|
|
|
2. Corrected Alarm ID 9 |
|
|
|
|
3. Modified Pipe ID and Orifce ID Configuration Data
Deciamls |
|
|
|
|
4. Logged Time and Date Changes to the Audit Report |
|
|
|
|
5. Modified Multivariable Interface Routine - Foxboro |
|
|
|
|
|
|
|
|
|
*Note:
Use MicroML4 Configuration Software Version 2.3 or newer |
|
|
|
|
|
|
6.01.10 |
10/1/2019 |
|
1. Corrected Solartron Calculation |
|
|
|
|
|
|
6.01.9 |
5/18/2018 |
|
1. Increased Timer for A/D
Converter (Analog Inputs) |
|
|
|
|
|
|
6.01.8 |
9/9/2013 |
|
1. Corrected Analog Input#3 Reading |
|
|
|
|
|
|
6.01.7 |
4/22/2013 |
|
1. Modified Communication Routine |
|
|
|
|
2. Reduced Sdevice Timer |
|
|
|
|
3. Set Display Contrast Initialization to 35 |
|
|
|
|
4. Set Double Write to Download Mode via RS232 Port |
|
|
|
|
5. Set Less Sensitivity Default Value for the Display Keys |
|
|
|
|
|
|
6.01.6 |
10/3/2011 |
|
1. Modified Calibration Mode for
Each Meter |
|
|
|
|
|
|
6.01.5 |
9/26/2011 |
|
1. Added API2004
Crude/Refined/Special Product Tables(Replacements for 23/24A,53/54A) |
|
|
|
|
2. Correction - F Factor (Metric unit ) |
|
|
|
|
|
|
6.01.3 |
3/31/2010 |
|
1. Modified Reset Routine |
|
|
|
|
|
|
6.01.2 |
1/29/2010 |
|
1. Added Rosemount Meter Type |
|
|
|
|
|
|
6.01.1 |
9/16/2009 |
|
1. Modified Display Initialization |
|
|
|
|
|
|
6.01.0 |
6/4/2009 |
|
1. Added Support for Old and New
Hardware Units |
|
|
|
|
|
|
6.00.14 |
11/4/2008 |
|
1. Add Water Product Option |
|
|
|
|
|
|
6.00.13 |
3/7/2008 |
|
1. New Rosemount Average Routine |
|
|
|
|
2. Correction - Read Analog Input Expansion Configuration |
|
|
|
|
|
|
6.00.12 |
4/4/2007 |
|
1. Correction - Digital Output |
|
|
|
|
|
|
6.00.11 |
1/8/2007 |
|
1. Modify Display Sensitivity Key
Routine |
|
|
|
|
|
|
6.00.10 |
11/9/2006 |
|
1. Correction - Slave Density/SG
Reading |
|
|
|
|
|
|
6.00.09 |
10/12/2006 |
|
1. Add Mass Pulse Option |
|
|
|
|
|
|
6.00.8 |
7/3/2006 |
|
1. Correction - Gravity Out of Range Volume Re-Calculation
for a New Product |
|
|
|
|
|
|
6.00.7 |
7/15/2005 |
|
1. Add Daylight Saving Time Option |
|
|
|
|
2. Correction - Analog Output - PID Control |
|
|
|
|
3. Modify Display Sensitivity Factor |
|
|
|
|
4. Correction - Flow Weighted Value for the Mixed Flow
Equations |
|
|
|
|
|
|
6.00.6 |
12/1/2004 |
|
1. Modify Modbus Shift Routine |
|
|
|
|
2. Modify Boolean Statement/Program Variable Statement
Routine |
|
|
|
|
3. Add Battery Voltage Reading |
|
|
|
|
4. Enable/Disable Front Panel Scan Key |
|
|
|
|
5. Enable/Disable Display Backlight Function |
|
|
|
|
6. Add Calibration Parameters to be Part of the
Configuration Software |
|
|
|
|
|
|
6.00.5 |
8/17/2004 |
|
1. Add TPU Frequency Counters |
|
|
|
|
2. Correction - Modbus ASCII Mode |
|
|
|
|
|
|
6.00.4 |
5/20/2004 |
|
1. Correction - Broadcast Command |
|
|
|
|
2. The 3rd Frequency Can Be Density Frequency or Meter
Frequency |
|
|
|
|
|
|
6.00.3 |
2/12/2004 |
|
1. Correction - Analog Output #1
With Analog Expansion Board Option |
|
|
|
|
|
|
6.00.2 |
2/11/2004 |
|
1. Correction - Retroactive Meter
Factor |
|
|
|
|
|
|
6.00.1 |
10/24/2003 |
|
1. Volume will roll over at