| MICROMS4 Image Release History | ||||
| Version | Release Date | Changes | ||
| 6.04.24 | 10/16/2025 | 1. Enabled Turbine Diagnostic Mode | ||
| 6.04.23 | 6/5/2025 | 1. Added Dynacone Wet Gas Flow Equation | ||
| 2. Added ISO6976-2016 Heating Value (Gross Method) | ||||
| 3. Adjusted Timer | ||||
| 6.04.22 | 5/4/2021 | 1.Supported Different Ranges of Foxboro Sensor | ||
| 6.04.21a | 7/27/2020 | 1. Added Delay Timer for Polling a Slave Unit. | ||
| 6.04.21 | 5/30/2018 | 1. Reset Turbine Offset at Startup | ||
| 6.04.20 | 5/11/2018 | 1. Added Foxboro Transmitter Interface | ||
| 2. Increased Timer for A/D Converter (Analog Inputs) | ||||
| 6.04.19 | 10/16/2017 | 1. Added NIST10-Superheated Steam | ||
| 2. Adjusted Timer for A/D Converter | ||||
| 6.04.18 | 11/2/2016 | 1. Corrected Energy Flow Calculation (Metric Units) | ||
| 6.04.17 | 12/2/2015 | 1 .Added Calorific Calculation | ||
| 6.04.16 | 9/1/2015 | 1. Modified Multivariable Data Dump Routine | ||
| 6.04.15 | 8/16/2015 | 1. Added Mutivariable Data Dump | ||
| 6.04.14 | 9/9/2013 | 1. Corrected Analog Input#3 Reading | ||
| 6.04.13 | 7/16/2013 | 1. Set Turbine Meter (GAS) to Liquid Meter Application if Composition Flag is Configured | ||
| 6.04.11 | 4/30/2013 | 1. Modified Communication Routine | ||
| 2. Reset Flow Averaged Value if a New Flow Calculation Method is Applied. | ||||
| 3. Set Less Sensitivity Default Value for the Display Keys | ||||
| 6.04.10 | 3/15/2013 | 1. Reduced Sdevice Timer | ||
| 2. Implemented API 2004 Crude Volume, Set Ct,anp to CTPL | ||||
| and set Base Density to Density@15 (Metric Units) | ||||
| 3. New Display Contrast Initialization | ||||
| 4. Display Analog Input Maintenance/Live Value without Setting High Limit (Fail Code=2) | ||||
| 5. Set Double Write to Download Mode via RS232 Port | ||||
| 6.04.09 | 10/25/2012 | 1. Modified Communcation Routine | ||
| 6.04.08 | 6/1/2012 | 1. Added Accelabar Equation | ||
| 2. Added Venturi Equation | ||||
| 3. Correction AGA7 - Mass Flow | ||||
| 6.04.07 | 12/16/2011 | 1. Correction - Poll Meter#2,#3, and #4 Historical Reports | ||
| 2. Allowing Zero Based Temperature | ||||
| 6.04.06 | 2/20/2011 | 1. Activated Slave Port and Digital In/Output#4 (Model 2009 or Newer Board) | ||
| 6.04.05 | 4/28/2010 | 1. Added ISO 6976 | ||
| 6.04.04 | 3/31/2010 | 1. Modified Reset Routine | ||
| 6.04.03 | 1/29/2010 | 1. Added Rosemount Meter Type | ||
| 6.04.02 | 9/16/2009 | 1. Modified Display Initialization | ||
| 6.04.01 | 5/29/2009 | 1. Addeed Pitot Tube Equation | ||
| 2. Added Modbus 2370 (1=New Hardware) | ||||
| 6.04.00 | 3/25/2009 | 1. Addeed Support for Old and New Hardware Units | ||
| 6.03.16 | 3/6/2008 | 1. Modify Audit Trail Routine | ||
| 2. Correction - Read Analog Input Expansion Configuration | ||||
| 6.03.15 | 11/14/2007 | 1. Correction - Reset Test Data - No Flow | ||
| 6.03.14 | 5/2/2007 | 1. Add - Gravity Factor and Base Density Factor | ||
| 2. Correction - Verabar Equation - Mass and Energy Flow Rate | ||||
| 6.03.13 | 1/23/2007 | 1. Correction - Daily FWA BS&W | ||
| 6.03.12 | 1/8/2007 | 1. Modify Display Sensitivity Key Routine | ||
| 6.03.11 | 7/21/2006 | 1. Add BS&W Input Option | ||
| 6.03.10 | 11/4/2005 | 1. Correction - Update Analog Output mA Value | ||
| 6.03.9 | 4/29/2005 | 1. Add - Verabar Flow Equation for Gas and Liquid Application | ||
| 6.03.8 | 3/16/2005 | 1. Add - Daylight Saving Time Option | ||
| 2. Add 16 Bits Month, Day, Year, Hour, Minute, and Second Registers | ||||
| 6.03.7 | 12/1/2004 | 1. Enable/Disable Front Panel Scan Key | ||
| 2. Add Turbine Diagnostic Data | ||||
| 3. Add Calibration Parameters to be Part of the Configuration Software | ||||
| 6.03.6 | 10/8/2004 | 1. Modify Modbus Shift Routine | ||
| 2. Modify Program Variable Statements and Boolean Statements Routine | ||||
| 6.03.5 | 9/2/2004 | 1. Add Gas Composition Selection | ||
| 2. Add TPU Frequency Counters | ||||
| 6.03.4 | 6/10/2004 | 1. Add Battery Voltage Reading | ||
| 6.03.3 | 5/21/2004 | 1. Correction - Broadcast Command | ||
| 6.03.2 | 5/18/2004 | 1. Correction - Update Gas Composition for All Meters On Snapshot Report. | ||
| 2. Correction - Liquid Meter Using AGA7 Method | ||||
| 6.03.1 | 4/29/2004 | 1. Correction - Analog Output Display mA | ||
| 6.03.0 | 2/20/2004 | 1. Add 485 Port#2 or Digital Output#4 Option | ||
| 2. Correction - Slave ECHART or MICROMV Message Initialization | ||||
| 6.02.9 | 1/21/2004 | 1. Correction - Update Gas Composition of Snapshot Report if G.C. is configured. | ||
| 6.02.8 | 1/2/2004 | 1. V-Cone Fow Equation - Add Y Factor Selection, Cone Thermal Coefficient | ||
| 6.02.7 | 12/2/2003 | 1. Correction - AGA7 Mass Calculation | ||
| 6.02.6 | 11/18/2003 | 1. Correction - Modbus IEEE Floating 2 Registers per One Variable (No. of Variables) | ||
| 6.02.5 | 10/27/2003 | 1. Set ROM/RAM Wait State to 1 | ||
| 6.02.4 | 9/8/2003 | 1. Add Three Frequency Inputs Selection - AGA7 | ||
| 6.02.3 | 8/28/2003 | 1. V-Cone Calculation - Add Pipe and Cone Thermal Coefficient | ||
| 6.02.2 | 7/24/2003 | 1. Correction - Write Modbus Floating Point 2 Registers 4 Bytes Variables | ||
| 2. Improve Real Time Clock Accuracy | ||||
| 6.02.1 | 7/15/2003 | 1. Add BS&W Override | ||
| 2. Add Natural Gas @20 Deg.C Flow Equation | ||||
| 3. Add Liquid Crude Volume to 20 Deg.C Equation | ||||
| 6.02.0 | 4/23/2003 | 1. Add Data Verification/Calibration Report | ||
| 6.01.9 | 3/7/2003 | 1. Correction - Update Liquid AGA7 Meter Factor and Frequency Data | ||
| 6.01.8 | 3/3/2003 | 1. Reset Slave Variables If Slave ID Is Changed Back To Zero. | ||
| 2. Default Display Timer to 4 | ||||
| 6.01.7 | 2/25/2003 | 1. Add Gas/Liquid Application Selection (Liquid - Table 24A, API 11.2.1) | ||
| 2. Add 4 Slaves-ECHART Interface | ||||
| 3. Modify Foxboro Interface and calculation | ||||
| 6.01.6 | 1/22/2003 | 1. Add 2368 IEEE Floating Point Modbus Selection 0=One 32 bits, 1=Two 16 bits Data | ||
| 2. Add 2368 IEEE Floating Point Modbus Sequence 0=HI,LO 1=LO,HI Bytes | ||||
| 3. Add 7352 Day Start Hour | ||||
| 4. Add Security Code Variables for the Window Program. | ||||
| 5. Modify Foxboro Interface and calculation | ||||
| 6.01.5 | 12/27/2002 | 1. Add Foxboro Interface | ||
| 2. Correction - Data Entry Through Front Panel Display | ||||
| 6.01.4 | 12/19/2002 | 1. Normalize AGA8 Composition Percentage. (Acceptable Data Range 98-102) | ||
| 2. Add Gas or Liquid Application | ||||
| 3. Add Flowing Density Override Entries | ||||
| 4. Add Station Total Selection | ||||
| 5. Correction - Program Variables | ||||
| 6. Add Historical Data - Program Variables | ||||
| 7. Enable PID Routine | ||||
| 8. Add Previous Day's Gross, Net, Temperature, Pressure 32 Bits Integer Modbus Registers | ||||
| 6.01.3 | 10/23/2002 | 1. Add Spare Data - RTD | ||
| 6.01.2 | 10/18/2002 | 1. Special Project - Test Data | ||
| 6.01.1 | 9/20/2002 | 1. Add New Data Entry - "Frequency I/O Postion Selection" | ||
| 2. Add "Test Data" | ||||