MICROMS4 Image Release History |
|
|
|
|
|
|
Version |
Release Date |
|
Changes |
|
|
|
|
|
|
6.04.22 |
5/4/2021 |
|
1.Supported Different Ranges of Foxboro Sensor |
|
|
|
|
|
|
6.04.21a |
7/27/2020 |
|
1. Added Delay Timer for Polling a Slave Unit. |
|
|
|
|
|
|
6.04.21 |
5/30/2018 |
|
1. Reset Turbine Offset at Startup |
|
|
|
|
|
|
6.04.20 |
5/11/2018 |
|
1. Added Foxboro Transmitter
Interface |
|
|
|
|
2. Increased Timer
for A/D Converter (Analog Inputs) |
|
|
|
|
|
|
6.04.19 |
10/16/2017 |
|
1. Added NIST10-Superheated Steam |
|
|
|
|
2. Adjusted Timer for A/D Converter |
|
|
|
|
|
|
6.04.18 |
11/2/2016 |
|
1. Corrected Energy Flow
Calculation (Metric Units) |
|
|
|
|
|
|
6.04.17 |
12/2/2015 |
|
1 .Added Calorific Calculation |
|
|
|
|
|
|
6.04.16 |
9/1/2015 |
|
1. Modified Multivariable Data Dump
Routine |
|
|
|
|
|
|
6.04.15 |
8/16/2015 |
|
1. Added Mutivariable Data Dump |
|
|
|
|
|
|
6.04.14 |
9/9/2013 |
|
1. Corrected Analog Input#3 Reading |
|
|
|
|
|
|
6.04.13 |
7/16/2013 |
|
1. Set Turbine Meter (GAS) to
Liquid Meter Application if Composition Flag is Configured |
|
|
|
|
|
|
6.04.11 |
4/30/2013 |
|
1. Modified Communication Routine |
|
|
|
|
2. Reset Flow Averaged Value if a New Flow Calculation
Method is Applied. |
|
|
|
|
3. Set Less Sensitivity Default Value for the Display Keys |
|
|
|
|
|
|
6.04.10 |
3/15/2013 |
|
1. Reduced Sdevice Timer |
|
|
|
|
2. Implemented API 2004 Crude Volume, Set Ct,anp to CTPL |
|
|
|
|
and set Base
Density to Density@15 (Metric Units) |
|
|
|
|
3. New Display Contrast Initialization |
|
|
|
|
4. Display Analog Input Maintenance/Live Value without
Setting High Limit (Fail Code=2) |
|
|
|
|
5. Set Double Write to Download Mode via RS232 Port |
|
|
|
|
|
|
6.04.09 |
10/25/2012 |
|
1. Modified Communcation Routine |
|
|
|
|
|
|
6.04.08 |
6/1/2012 |
|
1. Added Accelabar Equation |
|
|
|
|
2. Added Venturi Equation |
|
|
|
|
3. Correction AGA7 - Mass Flow |
|
|
|
|
|
|
6.04.07 |
12/16/2011 |
|
1. Correction - Poll Meter#2,#3,
and #4 Historical Reports |
|
|
|
|
2. Allowing Zero Based Temperature |
|
|
|
|
|
|
6.04.06 |
2/20/2011 |
|
1. Activated Slave Port and Digital
In/Output#4 (Model 2009 or Newer Board) |
|
|
|
|
|
|
6.04.05 |
4/28/2010 |
|
1. Added ISO 6976 |
|
|
|
|
|
|
6.04.04 |
3/31/2010 |
|
1. Modified Reset Routine |
|
|
|
|
|
|
6.04.03 |
1/29/2010 |
|
1. Added Rosemount Meter Type |
|
|
|
|
|
|
6.04.02 |
9/16/2009 |
|
1. Modified Display Initialization |
|
|
|
|
|
|
6.04.01 |
5/29/2009 |
|
1. Addeed Pitot Tube Equation |
|
|
|
|
2. Added Modbus 2370 (1=New Hardware) |
|
|
|
|
|
|
6.04.00 |
3/25/2009 |
|
1. Addeed Support for Old and New
Hardware Units |
|
|
|
|
|
|
6.03.16 |
3/6/2008 |
|
1. Modify Audit Trail Routine |
|
|
|
|
2. Correction - Read Analog Input Expansion
Configuration |
|
|
|
|
|
|
6.03.15 |
11/14/2007 |
|
1. Correction - Reset Test Data -
No Flow |
|
|
|
|
|
|
6.03.14 |
5/2/2007 |
|
1. Add - Gravity Factor and Base
Density Factor |
|
|
|
|
2. Correction - Verabar Equation - Mass and Energy Flow
Rate |
|
|
|
|
|
|
6.03.13 |
1/23/2007 |
|
1. Correction - Daily FWA BS&W |
|
|
|
|
|
|
6.03.12 |
1/8/2007 |
|
1. Modify Display Sensitivity Key
Routine |
|
|
|
|
|
|
6.03.11 |
7/21/2006 |
|
1. Add BS&W Input Option |
|
|
|
|
|
|
6.03.10 |
11/4/2005 |
|
1. Correction - Update Analog
Output mA Value |
|
|
|
|
|
|
6.03.9 |
4/29/2005 |
|
1. Add - Verabar Flow Equation for
Gas and Liquid Application |
|
|
|
|
|
|
6.03.8 |
3/16/2005 |
|
1. Add - Daylight Saving Time
Option |
|
|
|
|
2. Add 16 Bits Month, Day, Year, Hour, Minute, and Second
Registers |
|
|
|
|
|
|
6.03.7 |
12/1/2004 |
|
1.
Enable/Disable Front Panel Scan Key |
|
|
|
|
2. Add Turbine Diagnostic
Data |
|
|
|
|
3. Add Calibration Parameters to be Part of the
Configuration Software |
|
|
|
|
|
|
6.03.6 |
10/8/2004 |
|
1. Modify Modbus Shift Routine |
|
|
|
|
2. Modify Program Variable Statements and Boolean
Statements Routine |
|
|
|
|
|
|
6.03.5 |
9/2/2004 |
|
1. Add Gas Composition Selection |
|
|
|
|
2. Add TPU Frequency Counters |
|
|
|
|
|
|
6.03.4 |
6/10/2004 |
|
1. Add Battery Voltage Reading |
|
|
|
|
|
|
6.03.3 |
5/21/2004 |
|
1. Correction - Broadcast Command |
|
|
|
|
|
|
6.03.2 |
5/18/2004 |
|
1. Correction - Update Gas
Composition for All Meters On Snapshot Report. |
|
|
|
|
2. Correction - Liquid Meter Using AGA7 Method |
|
|
|
|
|
|
6.03.1 |
4/29/2004 |
|
1. Correction - Analog Output
Display mA |
|
|
|
|
|
|
6.03.0 |
2/20/2004 |
|
1. Add 485 Port#2 or Digital
Output#4 Option |
|
|
|
|
2. Correction - Slave ECHART or MICROMV Message
Initialization |
|
|
|
|
|
|
6.02.9 |
1/21/2004 |
|
1. Correction - Update Gas
Composition of Snapshot Report if G.C. is configured. |
|
|
|
|
|
|
6.02.8 |
1/2/2004 |
|
1. V-Cone Fow Equation - Add Y Factor Selection, Cone
Thermal Coefficient |
|
|
|
|
|
|
6.02.7 |
12/2/2003 |
|
1. Correction - AGA7 Mass
Calculation |
|
|
|
|
|
|
6.02.6 |
11/18/2003 |
|
1. Correction - Modbus IEEE
Floating 2 Registers per One Variable (No. of Variables) |
|
|
|
|
|
|
6.02.5 |
10/27/2003 |
|
1. Set ROM/RAM Wait State to 1 |
|
|
|
|
|
|
6.02.4 |
9/8/2003 |
|
1. Add Three Frequency Inputs
Selection - AGA7 |
|
|
|
|
|
|
6.02.3 |
8/28/2003 |
|
1. V-Cone Calculation - Add Pipe and Cone Thermal Coefficient |
|
|
|
|
|
|
6.02.2 |
7/24/2003 |
|
1. Correction - Write Modbus
Floating Point 2 Registers 4 Bytes Variables |
|
|
|
|
2. Improve Real Time Clock Accuracy |
|
|
|
|
|
|
6.02.1 |
7/15/2003 |
|
1. Add BS&W Override |
|
|
|
|
2. Add Natural Gas @20 Deg.C Flow Equation |
|
|
|
|
3. Add Liquid Crude Volume to 20 Deg.C Equation |
|
|
|
|
|
|
6.02.0 |
4/23/2003 |
|
1. Add Data
Verification/Calibration Report |
|
|
|
|
|
|
6.01.9 |
3/7/2003 |
|
1. Correction - Update Liquid AGA7
Meter Factor and Frequency Data |
|
|
|
|
|
|
6.01.8 |
3/3/2003 |
|
1. Reset Slave Variables If Slave
ID Is Changed Back To Zero. |
|
|
|
|
2. Default Display Timer to 4 |
|
|
|
|
|
|
6.01.7 |
2/25/2003 |
|
1. Add Gas/Liquid Application
Selection (Liquid - Table 24A, API 11.2.1) |
|
|
|
|
2. Add 4 Slaves-ECHART Interface |
|
|
|
|
3. Modify Foxboro Interface and calculation |
|
|
|
|
|
|
6.01.6 |
1/22/2003 |
|
1. Add 2368 IEEE Floating Point
Modbus Selection 0=One 32 bits, 1=Two 16 bits Data |
|
|
|
|
2. Add 2368 IEEE Floating Point Modbus Sequence 0=HI,LO
1=LO,HI Bytes |
|
|
|
|
3. Add 7352 Day Start Hour |
|
|
|
|
4. Add Security Code Variables for the Window Program. |
|
|
|
|
5. Modify Foxboro Interface and calculation |
|
|
|
|
|
|
6.01.5 |
12/27/2002 |
|
1. Add Foxboro Interface |
|
|
|
|
2. Correction - Data Entry Through Front Panel Display |
|
|
|
|
|
|
6.01.4 |
12/19/2002 |
|
1. Normalize AGA8 Composition
Percentage. (Acceptable Data Range 98-102) |
|
|
|
|
2. Add Gas or Liquid Application |
|
|
|
|
3. Add Flowing Density Override Entries |
|
|
|
|
4. Add Station Total Selection |
|
|
|
|
5. Correction - Program Variables |
|
|
|
|
6. Add Historical Data - Program Variables |
|
|
|
|
7. Enable PID Routine |
|
|
|
|
8. Add Previous Day's Gross, Net, Temperature, Pressure 32
Bits Integer Modbus Registers |
|
|
|
|
|
|
6.01.3 |
10/23/2002 |
|
1. Add Spare
Data - RTD |
|
|
|
|
|
|
6.01.2 |
10/18/2002 |
|
1. Special Project - Test Data |
|
|
|
|
|
|
6.01.1 |
9/20/2002 |
|
1. Add New Data Entry -
"Frequency I/O Postion Selection" |
|
|
|
|
2. Add "Test Data" |
|
|
|
|
|
|
|
|
|
|