MICROMVA Image Release History |
|
|
|
|
|
|
Version |
Release Date |
|
Changes |
|
|
|
|
|
|
6.04.04 |
5/27/2021 |
|
1. Added Foxboro Transmitter Interface |
|
|
|
|
2. Corrected unstable RTD Input Issue |
|
|
|
|
3. Replaced with ISO6976-2016 Gross Heating Value (AGA8
Detailed Method) |
|
|
|
|
|
|
6.04.03 |
5/30/2018 |
|
1. Reset Turbine Offset at Startup |
|
|
|
|
2. Increased Timer for A/D Converter (Analog Inputs) |
|
|
|
|
|
|
6.04.02 |
9/23/2013 |
|
1. Corrected Analog Input#3 Reading |
|
|
|
|
2. Modified Communication Routine |
|
|
|
|
3. Reduced Sdevice Timer |
|
|
|
|
|
|
6.04.1 |
3/28/2011 |
|
1. Increased Base Density
Resolution |
|
|
|
|
|
|
6.04.0 |
3/10/2011 |
|
1. Added Support for Old and New
Hardware Units |
|
|
|
|
2. Modified Display Initialization |
|
|
|
|
|
|
6.03.1 |
1/8/2007 |
|
1. Add Enable Battery Alarm Data
Entry (2621) |
|
|
|
|
2. Modify Display Sensitivity Key Routine |
|
|
|
|
3. Add Battery Voltage Floating Modbus Register (7098) |
|
|
|
|
4. New TPU Frequency Routine |
|
|
|
|
5. Correction - Analog Output #2 PID Assignment |
|
|
|
|
|
|
6.03.0 |
6/28/2004 |
|
1. Add Slave Gas Chromatograph
Status |
|
|
|
|
2. Correction - NBS1048 Nitrogen |
|
|
|
|
|
|
6.02.9 |
3/15/2004 |
|
1. Correction - Gas Chromatograph |
|
|
|
|
|
|
6.02.8 |
3/8/2004 |
|
1. Correction - Data Packet 16 Bits
Integer |
|
|
|
|
|
|
6.02.7 |
2/6/2004 |
|
1. Add Slave Gas Chromatograph |
|
|
|
|
|
|
6.02.6 |
10/27/2003 |
|
1. Set ROM/RAM Wait State to 1 |
|
|
|
|
|
|
6.02.5 |
8/15/2003 |
|
1. Reset Multi.Variable if
Multi.Var. Communication is Lost |
|
|
|
|
|
|
6.02.4 |
11/26/2002 |
|
1. Add 485 Port#2 or Digital
Input/Output#3 Option |
|
|
|
|
|
|
6.02.3 |
9/6/2002 |
|
1. Increase DP Range of
Muliti-Variable to 1075 |
|
|
|
|
|
|
6.02.2 |
8/6/2002 |
|
1. Correction - Analog Input
Jumping |
|
|
|
|
|
|
6.02.1 |
7/18/2002 |
|
1. Add Battery Voltage Routine |
|
|
|
|
2. Add New Modbus Registers - 1001s Alarm and Stauts Bits |
|
|
|
|
3. Add New Data Entry - Flow Density Override |
|
|
|
|
|
|
6.02.0 |
5/28/2002 |
|
1. Display - Add Premium Level
Cumulative Total |
|
|
|
|
2. Add Special Billing High/Low Signal |
|
|
|
|
|
|
6.01.5 |
3/7/2002 |
|
1. Run Switch - Use Net Flow Rate |
|
|
|
|
|
|
6.01.4 |
1/4/2002 |
|
1.Set Wait State to 2 |
|
|
|
|
|
|
6.01.3 |
11/19/2001 |
|
1. Correction - Swap Frequency #1
/#2 Modbus Registers |
|
|
|
|
|
|
6.01.2 |
10/17/2001 |
|
1. Correction - RTD Calibration |
|
|
|
|
|
|
6.01.0 |
8/20/2001 |
|
1. Add
Special Billing Function Through Status Inputs |
|
|
|
|
2. Correction - Analog Output Maximum |
|
|
|
|
|
|
6.00.2 |
7/17/2001 |
|
1. Add New Modbus Registers -
Premium Level |
|
|
|
|
2. Correction - Analog Output Drop |
|
|
|
|
|
|
6.00.1 |
6/10/2001 |
|
1. Correction - RTD Reading
(Increase RTD Gain) |
|
|
|
|
|
|
|
|
|
|