MICROMVG Image Release History
Version Release Date   Changes
       
6.09.17 6/29/2021 1. Added Gross/Mass/Energy Flow Units Options
  2. Added Delay Time between Slave Poll
  3. Added GC Variable 1x32 or 2x16 Selection
  4. Added ISO6976-2016 Heating Value (Gross)
  5. Supported Different Ranges of Foxboro Sensor
   
6.09.16 10/10/2019   1. Corrected Analog Inputs Expension Initialization
       
6.09.15 5/30/2018   1. Reset Turbine Offset at Startup
       
6.09.14 5/18/2018   1. Increased Timer for A/D Converter (Analog Inputs)
       
6.09.13 2/23/2018   1. Modified Foxboro Transmitter Interface Routine
       
6.09.12 6/6/2017   1. Reduced Time for A/D Converter
       
6.09.11 7/14/2016   1. Added Averaged Heating Value
  2. Log Heating Value Overriding Changes to Audit Trail Report
       
6.09.10 12/29/2015   1. Added Calorific Value
       
6.09.09 7/1/2015   1. Added Foxboro Transmitter Interface
       
6.09.08 9/9/2013   1. Corrected Analog Input#3 Reading
       
6.09.07 5/6/2013   1. Set Less Sensitivity Default Value for the Display Keys
  2. Correction - Densitometer Temperature Maintenance Value (Audit Trail Report)
       
6.09.06 3/12/2013   1. Modified Communication Routine
  2. Reduced Sdevice Timer
  3. Set Display Contrast Initialization to 35
  4. Set Double Write to Download Mode via RS232 Port
  5. Set Modbus Register <2611> to 1 for 2x16 bits Gas Chromatograph IEEE Float
   
6.09.05 9/14/2012   1. Correction - Flow Averaged Routine (AGA7 - Mass Pulses Input)
       
6.09.04 3/31/2010 1. Modified Reset Routine
  2. Correction - Printed Reports
  3. Correction - Stack DP 
       
6.09.03 1/29/2010 1. Added Rosemount Meter Type
       
6.09.02 10/12/2009   1. Included FPV in the Wedge Meter Equation for Gas Application
       
6.09.01 9/16/2009   1. Modified Display Initialization
       
6.09.00 3/20/2009   1. Added Support for Old and New Hardware Units
       
6.08.20 9/9/2008   1. Added Modbus Registers 9397,9399 for Meter#1/#2 Mass Flow Rate in LB
  2. Added Scale Variabes 3036 and 3028 (2 Decimal Inferred)
       
6.08.19 8/25/2008   1. Added Scale Value Selection
       
6.08.18 3/26/2008   1. Correction - Standard Steam Calculation
       
6.08.17 1/31/2008   1. New Rosemount Average Routine
       
6.08.16 2/26/2007 1. Added NIST10 Superheated Steam
  2. Added Yesterday Day and Last Hour Registers
   
6.08.15 1/8/2007   1. Modify Display Sensitivity Key Routine
       
6.08.14 11/28/2006   1. Added Floating Point Shift Registers
  2. Added Analog Input Expansion Option
       
6.08.13 11/9/2005   1. Added Day Flow Time in Minutes
       
6.08.12 10/5/2005   1. Added Proving Function
       
6.08.11 6/23/2005   1. Increase the Range of Saturated Steam Table
       
6.08.10 4/26/2005   1. Add PID Pressure Base
  2. Add Daylight Saving Time Option
  3. Add Multi.Variable Communication Status
       
6.08.9 11/30/2004   1. Modify Modbus Shift Routine
  2. Added Battery Voltage Reading
  3. Enable/Disable Front Panel Scan Key
  4. Enable/Disable Display Backlight Function
  5. Correction - V-Cone Y Factor
  6. Added Calibration Parameters to be Part of the Configuration Software
       
6.08.8 9/17/2004   1. Increased the Range of Saturated Steam Table
  2. Synchronize the System Clock and Realtime Clock
       
6.08.6 6/15/2004   1. Added New Modbus Shift Range (8001-8451)
       
6.08.5 6/8/2004   1. Increased Stack
  2. Correction - Frequency Input - Mass Pulse FWA Routine
       
6.08.4 4/20/2004   1. Correction - Broadcast Command
       
6.08.3 4/15/2004   1. Correction - Analog Ouput - Reverse Flow Rate
       
6.08.2 3/26/2004   1. Added Yesterday's Data Modbus Registers (8381-8435)
       
6.08.1 10/27/2003   1. Set ROM Wait State to 1
       
6.08.0 10/7/2003   1. Correction - Analog Output #2,#3,#4
  2. Correction - Modbus Registers 1801-1846
       
6.07.9 9/19/2003   1. Correction - RS232 Communication (Version 6.07.8 only) 
       
6.07.8 9/8/2003   1. Reset Multi.Variable if Multi.Var. Communication is Lost
  2. Set RAM Wait State to 1
       
6.07.7 11/15/2002   1. Normalize AGA8 Composition Percentage. (Acceptable Data Range 98-102)
   
  6.07.6 10/3/2002   1. Correction - Steam Entropy Calculation
   
6.07.5 9/6/2002   1. Incrased DP Range of Multi-Variable to 1075
   
6.07.4 8/26/2002   1. Correction - Analog Input Jumping
   
6.07.3 3/15/2002   1. Disable Calibrate Mode - Mass Flow Rate Data Entry
   
6.07.2 1/23/2002   1. Revised AGA8 Routine
   
6.07.1 1/3/2002   1. Set Wait State to 2
   
6.07.0 10/17/2001   1. Correction - RTD Calibration
   
6.06.9 8/20/2001   1. Correction - Analog Output Maximum
   
6.06.8 7/17/2001   1. Revised Communication Routine
   
6.06.7 7/10/2001   1. Correction - Analog Output Drop
   
6.06.6 6/10/2001   1. Correction - RTD Reading (Increase RTD Gain)
   
6.06.5 5/8/2001   1. Disable Analog Output if Calibration Is Set
   
6.06.4 4/23/2001   1. Correction - Density.b Calculation (AGA8 Gross Method#1/#2)
  2. Add New Modbus Registers - Analog Output#3/#4
       
6.06.1 4/15/2001 1. Added PID Control Routine
       
6.06.0 4/5/2001 1. Added Analog Output #1-#4 Routine
       
6.05.3 3/23/2001 1. Increased Sensitive Factor Value
       
6.05.2 3/16/2001 1. Added New Data Entry - FA Override (V-Cone Calculation)
       
6.05.1 2/7/2001 1. Swap Status Input/Switch Output #1/#4 Setting
       
6.05.0 11/23/2000 1. Revised Multi-Variable Interface Routine
       
6.04.0 10/23/2000 1. Added More Resolution to Totalizer
       
6.03.4 10/10/2000 1. Correction - Switch Outputs and Alarms
       
6.03.3 10/6/2000 1. Correction - Spare Data Alarms
  2. Set Data Ready Flag After Retrieving Historical Data
       
6.03.2 9/22/2000 1. Correction - Multi-Variable Calibration
       
6.03.1 9/5/2000 1. Correction - Analog Output Default
       
6.03.0 8/21/2000 1. Add Calibration
  2. Correction - Display Contrast
       
6.02.0 8/12/2000 1. Added Modem Function
   
6.01.0 8/4/2000   1. Correction - Calibration Mode